Paper Title
Controlling Of SEIG With V/F Controller In Standalone Conditions
Abstract
Induction generators are gradually more being employed in nonconventional energy systems for example wind,
micro/mini hydro, etc. The benefits of using an induction generator rather than a synchronous generator are eminent. Some
of them are condensed unit cost and size, roughness, brushless (in squirrel cage construction), lack of separate dc source,
simplicity of maintenance, self-protection versus severe overloads and short circuits, etc. In isolated systems, squirrel cage
induction generators with capacitor excitation, known as self-excited induction generators (SEIGs), are very popular. The
V/f control pattern for motoring function is properly developed to the SCIG for calculating both voltage build-up and
dynamic transients. The proposed system design is presented using MATLAB/SIMULINK.