Paper Title :
Protection Of Distribution Transformer Using Auto Protected System

Author :Sumit Kumar, A. S. Chatpalliwar

Article Citation :Sumit Kumar ,A. S. Chatpalliwar , (2015 ) " Protection Of Distribution Transformer Using Auto Protected System " , International Journal of Mechanical and Production Engineering (IJMPE) , pp. 13-16, Volume-3,Issue-3

Abstract : Distribution transformers are traditionally protected by differential protection schemes that use voltages and currents to detect abnormalities in the differential zone of protection. For this type of scheme, a short circuit or high magnitude current must be present to initiate a trip. However, this scheme might not be ideal when transformers need to be overloaded to mitigate contingency conditions. Using the IEEE Guide for Loading of Oil-Immersed Distribution Transformers, one can thermally rate transformers beyond their nameplate conditions to a level that is safe for operation. Using the guide, engineers can establish continuous, emergency and short term emergency transformer ratings. Operators can use these ratings until the contingency conditions are mitigated. However, once the transformer has surpassed the short term emergency ratings, the transformer might reach critical temperatures and could possibly sustain damage. Protection engineers can avoid further transformer damage by using the thermal protection principles of the IEEE standard. This paper discusses the fundamental thermal principles of distribution transformers, philosophies of operations and the implementations of thermal protection. Keywords- Oil Immersed, Thermal Protection.

Type : Research paper

Published : Volume-3,Issue-3


DOIONLINE NO - IJMPE-IRAJ-DOIONLINE-1807   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 83