International Journal of Mechanical and Production Engineering (IJMPE)
.
Follow Us On :
current issues
Volume-12,Issue-6  ( Jun, 2024 )
Past issues
  1. Volume-12,Issue-5  ( May, 2024 )
  2. Volume-12,Issue-4  ( Apr, 2024 )
  3. Volume-12,Issue-3  ( Mar, 2024 )
  4. Volume-12,Issue-2  ( Feb, 2024 )
  5. Volume-12,Issue-1  ( Jan, 2024 )
  6. Volume-11,Issue-12  ( Dec, 2023 )
  7. Volume-11,Issue-11  ( Nov, 2023 )
  8. Volume-11,Issue-10  ( Oct, 2023 )
  9. Volume-11,Issue-9  ( Sep, 2023 )
  10. Volume-11,Issue-8  ( Aug, 2023 )

Statistics report
Oct. 2024
Submitted Papers : 80
Accepted Papers : 10
Rejected Papers : 70
Acc. Perc : 12%
Issue Published : 135
Paper Published : 2420
No. of Authors : 6922
  Journal Paper


Paper Title :
Effect of Pulse Repetition Frequency of HIFU on in Vitro Thrombolysis

Author :Yufeng Zhou, Wenjing Yang

Article Citation :Yufeng Zhou ,Wenjing Yang , (2017 ) " Effect of Pulse Repetition Frequency of HIFU on in Vitro Thrombolysis " , International Journal of Mechanical and Production Engineering (IJMPE) , pp. 68-73, Volume-5,Issue-1

Abstract : Vascular occlusion by the thrombi is the main reason for ischemic stroke and deep vein thrombosis. High-intensity focused ultrasound (HIFU) and histotripsy or microtripsy pulses can effectively dissolve the blood clot with no use of thrombolytic agent and ultrasound contrast agent. In this study, HIFU bursts at the same duty cycle (2%) but varied pulse repetition frequency (PRF) from 1 Hz to 1000 Hz were delivered to in vitro porcine blood clot for 30 s. Thrombolysis efficiency initially increases slightly with the PRF, 86.4±10.3%, 89.9±11.9, and 92.9±12.8% at the PRF of 1 Hz, 10 Hz, and 100 Hz, respectively, without significant difference, but then drops dramatically to 37.9±6.9% at the PRF of 1000 Hz. The particle size in the supernatant of dissolution is 547.1±129.5 nm. Thrombi motion during HIFU exposure shows violent motion and significant curling at the low PRF, rotation about its axis with occasional curling at the moderate PRF, and localized vibration at the high PRF due to the generation of acoustic radiation force and streaming. Quantitative analysis of recorded motion shows the axial displacement decreases with the PRF of delivered HIFU bursts, from 3.9±1.5 mm at 1 Hz to 0.7±0.4 mm at 1000 Hz. Bubble cavitation during HIFU exposure to the blood clot was also monitored. The increase of PRF led to the increase of inertial cavitation but the decrease of stable cavitation. Index Terms- thrombolysis, high-intensity focused ultrasound (HIFU), pulse repetition frequency (PRF), clot motion.

Type : Research paper

Published : Volume-5,Issue-1


DOIONLINE NO - IJMPE-IRAJ-DOIONLINE-6765   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 74
| Published on 2017-03-09
   
   
IRAJ Other Journals
IJMPE updates
Volume-12,Issue-5 (May, 2024 )
The Conference World

JOURNAL SUPPORTED BY