International Journal of Advances in Mechanical and Civil Engineering (IJAMCE)
.
Follow Us On :
current issues
Volume-11,Issue-1  ( Feb, 2024 )
Past issues
  1. Volume-11,Issue-1  ( Feb, 2024 )
  2. Volume-10,Issue-6  ( Dec, 2023 )
  3. Volume-10,Issue-5  ( Oct, 2023 )
  4. Volume-10,Issue-4  ( Aug, 2023 )
  5. Volume-10,Issue-3  ( Jun, 2023 )
  6. Volume-10,Issue-2  ( Apr, 2023 )
  7. Volume-10,Issue-1  ( Feb, 2023 )
  8. Volume-9,Issue-6  ( Dec, 2022 )
  9. Volume-9,Issue-5  ( Oct, 2022 )
  10. Volume-9,Issue-4  ( Aug, 2022 )

Statistics report
May. 2024
Submitted Papers : 80
Accepted Papers : 10
Rejected Papers : 70
Acc. Perc : 12%
Issue Published : 58
Paper Published : 1075
No. of Authors : 2871
  Journal Paper


Paper Title :
Seismic Response of Tall Building with Underground Storey using Dampers

Author :G.D.Awchat, Yamini.N.Deshmukh

Article Citation :G.D.Awchat ,Yamini.N.Deshmukh , (2017 ) " Seismic Response of Tall Building with Underground Storey using Dampers " , International Journal of Advances in Mechanical and Civil Engineering (IJAMCE) , pp. 58-61, Volume-4,Issue-3

Abstract : As the seismic load acting on a structure is a function of the self-weight of the structure these structures are made comparatively light and flexible which have relatively low natural damping. Results make the structures more vibration prone under wind, earthquake loading. New generation high rise building is equipped with artificial damping device for vibration control through energy dissipation. A tuned mass damper is a device consisting of a mass, a spring, and a damper that is attached to a structure in order to reduce the dynamic response of the structure. The frequency of the damper is tuned to a particular structural frequency so that frequency is excited, the damper will resonate out of phase with the structural motion. Energy is dissipated by the damper inertia force acting on the structure. This research investigates seismic response of building structures with underground stories and embedded dampers. The main response parameters are tip deflection and tip acceleration of the structure. This building has been modelled as 3D Space frame model with six degree of freedom at each node using SAP 2000 software for stimulation of behaviour under gravity and seismic loading. Tuned mass dampers are considered and used for different locations of the structure. Time history method of dynamic analysis is used by SAP2000 software. Keywords - Dampers, dynamic response, flexible, frequency, spring, Time history, Tuned mass.

Type : Research paper

Published : Volume-4,Issue-3


DOIONLINE NO - IJAMCE-IRAJ-DOIONLINE-8287   View Here

Copyright: © Institute of Research and Journals

| PDF |
Viewed - 62
| Published on 2017-08-11
   
   
IRAJ Other Journals
IJAMCE updates
IJAMCE Vol-11, Iss-1 (Feb 2024)
The Conference World

JOURNAL SUPPORTED BY